<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-27 03-48-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 49 dBuV R-PCE
Pilot RDS Phase Difference
6.0 kHz 3.0 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
12 kHz 48 kHz 18944 0,2323
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,3 dBr -1,83 dBr -1,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 3:48, 27.05.2024
RT
"Zpravy z regionu - rozhovory - dobre rady - souteze "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 48 kHz MIN: 12 kHz % above 77 kHz: 0,2323 Acquired: 2024/05/27 3:48:18 Total samples: 18944 Equivalent time: 0:15:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -1,1 dBr MIN: -2,3 dBr AVE: -1,83 dBr % above 0,2 dBr: 0,0 Last value: -1,4 dBr (2024/05/27 3:48:17) 03:34 03:36 03:38 03:40 03:42 03:44 03:46 03:48 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality